Vertical Cavity Surface Emitting Laser (VCSEL) Flood Illuminator Series Datasheet
Features | Application |
Size(mm): 25.5x7.4x1.5mm | TOF |
AlN ceramic package | Volume measurement, 3D scanning |
Peak wavelength 940nm | Avoidance |
3*11 VCSEL Array | AR/VR |
High reliability |
|
1. Absolute Maximum Ratings(Ta=25°C)
Parameter | Values | Values |
Operation temperature | TOPR | -20oC to 85oC |
Storage temperature | Tstg | -40oC to 105oC |
Max Forward Current(CW) | Ifmax | 7.5A |
Max Forward Current(Pulsed,DC=10%,Tp=1ms) | Ifpmax | 16.5A |
Soldering Temperature | TSTG | 260oC for 5sec |
2. Electrical-optical characteristics
Electrical-optical characteristics of VCSEL (Ts =25 °C) |
Parameter | Symbol | Test Condition | Min | Typ | Max | Unit |
Peak Wavelength | λp | IF = 10.5A,DC=10%,Tp=1ms | 930 | 940 | 950 | nm |
Threshold Current | Itc | - | 1.5 | 2.1 | 3.6 | A |
Forward Voltage | VF | IF = 10.5A,DC=10%,Tp=1ms | -
| 53.9 | 57.2 | V |
Output Power | Φe | IF = 10.5A,DC=10%,Tp=1ms | 86
| 92 | 96 | W |
Beam Divergence(FW D86) | θ | IF = 10.5A,DC=10%,Tp=1ms | 20
| 23 | 26 | Deg |
Slope Efficiency | SE | - | - | 30 | - | W/A |
Power Conversion Efficiency | η | IF = 10.5A,DC=10%,Tp=1ms | -
| 48% | - | - |
3. Package Outline
Note: 1. Unit: mm; 2. Tolerance: ±0.15mm
4. Reflow Soldering Characteristics
Profile Feature | Pb-Free (SnAgCu) Assembly |
Preheat/Soak Temperature Min (Tsmin) Temperature Max (Ts max) Time (ts) from (Tsmin to Tsmax) | 150°C 200°C 60-120 seconds |
Ramp-up rate (TL to Tp) | 3°C/second max. |
Liquidous temperature (TL) Time (h) maintained above TL | 217°C 60-150 seconds |
Peak package body temperature (Tp) | 260°C |
Time within 5°C of actual Peak Temperature (tp) | 30 seconds |
Ramp-down rate (Tp to TL) | 6°C/second max. |
Time 25°C to peak temperature | 8 minutes max. |
5. Other Caution
■ VCSEL is very sensitive to Electrostatic discharge (ESD) and Electrical over stress (EOS), excessive ESD/EOS have damage the chip and result in performance degradation. Please make sure during the whole usage and installation process does not exist to affect the VCSEL.
■ VCSEL can also be damaged by electrical surge, please make sure any driving electrical circuits are equipped with surge protection.
■ During the installation process, please make sure all the equipment and personnel are grounded properly and production environment should make use of ion-blowers, ESD protection equipment such as anti-static gloves,anti-static wrist bands, anti-static mats, anti-static clothes, anti-static shoes and anti-static containers.
6. Revision History
Created by:
Version | Subjects(major change in previous version) | Date of change |
RD0 | First public | Jul.22.2024 |